Answer
May 19, 2023 - 07:21 AM
Remove the nozzle filters for a 20% increase in efficiency. The trick to keeping nozzles clean is to keep the mixing tank clean inside the Gen 3 unit. Also do an inspection every time you fill it with new chemical and blow water through the circuit and nozzles. You can also remove a few of the nozzles downline and flush the lines of all the sediment that accumulates. If you do this, there is no need for the external filter on a Gen 3. They are more problematic in my opinion. Keep the system clean, flushed and sanitary, don't let mold grow inside the tank or lines and you will have a great working system. If you want the external filter, order the Gen 1.3 and specify in the notes that you have a Gen 3 or call us at 1-855-553-7378.
Ron
Ron
Add New Comment